Kindly follow the below procedure:
* Press and hold mute and display key simultaneously for two seconds.
* The UPS will beep to indicate that the feature is disabled.
* The leaf icon on the display will disappear.
* Power saving mode is now disabled.
Kindly follow the below steps:
Press and hold mute key for few seconds.
If the line through the speaker icon is not illuminated.
Now the audible alarm has been turned on.
This is due to Display Power-Saving mode. To turn on the display , follow below steps.
Press and hold DISPLAY button for two seconds.
NOTE :While in Power-Saving Mode, the display will illuminate if a button is pressed,
it then goes dark after 60 seconds of no activity.
The Master Outlet threshold may be incorrectly set.
Solution : Adjust the threshold when the Master outlet signals the Controlled outlets to
shut down.
1. Ensure a master device is connected to the Master outlet. Put that device
into Sleep or Standby mode, or turn it OFF.
2. Press DISPLAY and MUTE simultaneously and hold for six seconds, until
the leaf icon flashes three times and the Back-UPS beeps three times.
3. The Back-UPS will now recognize the threshold level of the Master
device and save it as the new threshold setting.
1. Ensure a master device is connected to the Master outlet. Put that device into Sleep or
Standby mode, or turn it OFF.
2. Press DISPLAY and MUTE simultaneously and hold for six seconds, until the leaf icon flashes
three times and the Back-UPS beeps three times.
3. The Back-UPS will now recognize the threshold level of the Master device and save it as the
new threshold setting.
Setting the threshold. The amount of power used by a device in Sleep or Standby mode varies
between devices. It may be necessary to adjust the threshold at which the Master outlet signals
the Controlled outlets to shutdown.
APC 1KVA (BR1000G-IN) UPS is with LCD Display, communication port and having auto shutdown
features, where as 1.1 KVA having LED Display, no communication port and not having auto
shutdown features.